Approx. Rs 252 / MeterGet Latest Price
Product BrochureProduct Details:Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 35 Sq mm2 |
Maximum Diameter | 0.21 mm(Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.554 ohm/km (@ 20 deg C 85% Duty Cycle) |
Class | 6 |
Standards | IS 8130:1984 |
Approx. Rs 190 / MeterGet Latest Price
Product Details:Minimum Order Quantity | 2000 Meter |
Length | 25 sq.mm |
Type | Batterry and Battery Charging Equipment |
Withstands Temperature | Upto 90 deg C |
Manufactured Using | 100 % Electrolytic & Oxygen Free Copper Conductor |
Nominal Cross Sectional Area of Conductor | 35 Sq mm2 |
Maximum Diameter | 0.21 (Of %kW.S In Conductor) |
Maximum Resistance | 0.554 (Of Conductor @ 20deg C 85% Duty Cycle) |
Additional Information:
Approx. Rs 675 / MeterGet Latest Price
Product Details:Minimum Order Quantity | 1000 Meter |
Number of Cores | Single,2,3,4,5 |
Conductor Material | Copper |
Min Size | 25.00 sq.mm |
Max Size | 95 sq.mm |
Nominal Cross Sectional Area of Conductor | 95 |
Maximum Diameter | 0.31 ( Of %kW.S In Conductor) |
Maximum Resistance | 0.206 ( Of Conductor @ 20deg C 85% Duty Cycle) |
We at Viral Electronics manufacture Superflex Battery Cables 95 Sq.mm used to manufacture bolted connectors used for 2-volt traction batteries.
Feature:
Details :
Current Rating of General Service Normal Duty Elastomeric Compound Covered Cable with Copper Conductor:
Nominal Cross-Sectional Area of Conductor | FLEXIBLE COPPER CONDUCTORS FOR SINGLE-CORE AND CABLES, CLASS 6 | |
MAXIMUM DIAMETERS OF IN CONDUCTOR | MAXIMUM RESISTANCE OF CONDUCTOR @ 20°C 85% Duty Cycle | |
(1) | (2) | (3) |
Sq mm2 | mm | Ohms/km |
10 | 0.2 | 1.91 |
16 | 0.2 | 1.21 |
25 | 0.2 | 0.780 |
35 | 0.2 | 0.554 |
50 | 0.2 | 0.386 |
70 | 0.2 | 0.272 |
95 | 0.2 | 0.206 |
Approx. Rs 190 / MeterGet Latest Price
Product Details:Minimum Order Quantity | 1000 Meter |
Power/Voltage | 650/1100 Volts |
Min Size | 25.00 sq.mm |
Max Size | 95 sq.mm |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 25 |
Maximum Diameter | 0.21 (Of %kW.S In Conductor) |
Maximum Resistance | 0.780 (Of Conductor @ 20 deg C 85% Duty Cycle) |
We at Viral Electronics manufacture Standard Battery Cables 25 Sq.mm used for Battery Charging units Useful as Auto Mobile Battery Cable, Solar Batteries, Inverters, Gensets.
Features:
Details :
Current Rating of General Service Normal Duty Elastomeric Compound Covered Cable with Copper Conductor:
Nominal Cross-Sectional Area of Conductor | FLEXIBLE COPPER CONDUCTORS FOR SINGLE-CORE AND CABLES, CLASS 6 | |
MAXIMUM DIAMETER OF %kW.S IN CONDUCTOR | MAXIMUM RESISTANCE OF CONDUCTOR @ 20°C 85% Duty Cycle | |
(1) | (2) | (3) |
Sq mm2 | mm | Ohm/km |
10 | 0.21 | 1.91 |
16 | 0.21 | 1.21 |
25 | 0.21 | 0.780 |
35 | 0.21 | 0.554 |
50 | 0.31 | 0.386 |
70 | 0.31 | 0.272 |
95 | 0.31 | 0.206 |
Approx. Rs 60 / MeterGet Latest Price
Product Details:Minimum Order Quantity | 500 Meter |
Number Of Core | Single, 2, 3, 4, 5 |
Insulation Material | PVC |
Type | Battery Cable |
Material | Copper |
Nominal Cross Sectional Area of Conductor | 240 sq mm2 |
Maximum Diameter | 0.5 (Of %kW.S In Conductor) |
Maximum Resistance | 0.08 (Of Conductor @ 20 deg C 85% Duty Cycle) |
We at Viral Electronics manufacture PVC Insulated Battery Cables used forBattery Charging units in battery industries, in automobiles, railways, Traction forklift Charger, Solar Batteries.
Feature:
Details :
Current Rating of General Service Normal Duty PVC Compound Covered Cable with Copper Conductor:
|
Approx. Rs 190 / MeterGet Latest Price
Product Details:Number of Cores | Single, 2, 3, 4, 5 |
Conductor Material | Copper |
Insulation Material | PVC |
Type | Battery Cable |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 35 Sq mm2 |
Maximum Diameter | 0.4 (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.554 (@ 20 deg C 85% Duty Cycle) |
Approx. Rs 60 / MeterGet Latest Price
Product Details:Number of Cores | Single, 2, 3, 4, 5 |
Conductor Material | Copper |
Insulation Material | PVC |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 4 sq mm2 |
Maximum Diameter | 0.3 mm (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 4.95 (@ 20 deg C 85% Duty Cycle) |
Approx. Rs 362 / MeterGet Latest Price
Product Details:Size | 50 SQ.MM |
Brand | VIRAL CABLES AND WIRES |
Length | 500 METERS |
I deal in | New Only |
Maximum Diameter | 0.31 mm( Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.386 ohm/km (@ 20 deg C 85% Duty Cycle) |
Nominal Cross Sectional Area of Conductor | 50 sq mm2 |
Standards | IS 81301984 |
Class | 6 |
Max Withstand Temperature | 90 deg C |
Approx. Rs 510 / MeterGet Latest Price
Product Details:Number of Cores | Single Core |
Class | 6 |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 70 Sq mm2 |
Maximum Diameter | 0.31 mm (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.272 km (@ 20 deg C 85% Duty Cycle) |
Standards | IS 8130:1984 |
Approx. Rs 675 / MeterGet Latest Price
Product Details:Number of Cores | Single Core |
Standards | IS 8130:1984 |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 95 sq mm2 |
Maximum Diameter | 0.31 mm (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.206 km (@ 20 deg C 85% Duty Cycle) |
Class | 6 |
Approx. Rs 252 / MeterGet Latest Price
Product Details:Number of Cores | Single Core |
Class | 6 |
Standards | IS 8130:1984 |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 35 Sq mm2 |
Maximum Diameter | 0.21 mm (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.554 km (@ 20 deg C 85% Duty Cycle) |
Approx. Rs 362 / MeterGet Latest Price
Product Details:Number of Cores | Single Core |
Class | 6 |
Standards | IS 8130:1984 |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 50 sq mm2 |
Maximum Diameter | 0.31 mm (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.386 km (@ 20 deg C 85% Duty Cycle) |
Approx. Rs 510 / MeterGet Latest Price
Product Details:Class | 6 |
Standards | IS 8130:1984 |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 70 Sq mm2 |
Maximum Diameter | 0.31 mm (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.272 km (@ 20 deg C 85% Duty Cycle) |
Approx. Rs 675 / MeterGet Latest Price
Product Details:Class | 6 |
Standards | IS 8130:1984 |
Max Withstand Temperature | 90 deg C |
Nominal Cross Sectional Area of Conductor | 95 sq mm2 |
Maximum Diameter | 0.31 mm (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.206 km (@ 20 deg C 85% Duty Cycle) |
Approx. Rs 180 / MeterGet Latest Price
Product Details:Number of Cores | Single Core |
Conductor Material | Copper |
Insulation Material | PVC |
Nominal Cross Sectional Area of Conductor | 70 Sq mm2 |
Maximum Diameter | 0.4 (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.272 (@ 20 deg C 85% Duty Cycle) |
Max Withstand Temperature | 90 deg C |
Inverter Battery Cables offered are ideal for installing on professional power inverters and are offered in different finish specifications.
Features:
Details:
Approx. Rs 250 / MeterGet Latest Price
Product Details:Minimum Order Quantity | 300 Meter |
Size | 25 SQ.MM |
Brand | VIRAL CABLES & WIRES |
Length | 500 METERS |
Finish Type | MATT |
Material | COPPER AND TPV |
Number of Cores | SINGLE CORE |
Diameter | 11.5 mm |
Conductor Material | Copper |
Insulation Material | Thermo-Plastic Rubber |
Pack Size | 100 METERS |
Packaging Type | SELF WOUND COILS / DRUMS |
Temperature Rating | 90 Degrees maximum. |
Type | TRACTION BATTERY CABLES |
Model Number | 25 SQ.MM |
Conductor Resistance | .780 OHMS/KM @ 20 DEGREES CENTIGRADE |
Condition | BRAND NEW |
Max Withstand Temperature | 90 deg C |
Maximum Resistance Of Conductor | 0.780 (@ 20 deg C |
Nominal Cross Sectional Area of Conductor | 25 Sq mm. |
Maximum Diameter | 11.5 MM |
TRACTION BATTERY CABLES
These Cables can be offered in THERMOPLASTIC RUBBER INSULATION.
Features:
Details:
Approx. Rs 180 / MeterGet Latest Price
Product Details:Minimum Order Quantity | 1000 Meter |
Number of Cores | Single, 2, 3, 4, 5 |
Insulation Material | PVC |
Material | Copper |
Nominal Cross Sectional Area of Conductor | 150 sq mm2 |
Maximum Diameter | 0.5 (Of %kW.S In Conductor) |
Maximum Resistance Of Conductor | 0.129 (@ 20 deg C 85% Duty Cycle) |
Max Withstand Temperature | 90 deg C |
Battery Cables offered comes with insulation support of 90C PVC as well as copper or tinned copper conductor support.